Lot Screening
Even if the defects are detected at Level 1 or Level 2, the lot could contain good parts. The final customer can purchase the lot containing defective parts, because these components are hard to find. The customer has to screen the lot in order to remove defective parts before storage in order to guarantee the components reliability. Our goal is to assist our customers in this approach by establishing a group of tests, for example:
External visual inspection of all parts: to remove the parts with bad marking, damaged, corroded or contaminated leads, cracked package…
X-Rays inspection of all parts: to check the die size, internal wires, die attachment quality...
Acoustic microscopy of all parts: to remove unacceptable delaminated part.
Electrical testing of all parts: functional test if required at the limits of component specification based on existent test solutions or specific solutions developed by a test team.
Assembly simulation and cycling ageing tests: to simulate the stress the components will be subjected to (during assembly process or when using on the application) followed by acoustic microscopy, internal wires pull tests or functional electrical tests.
Leads re conditioning (in an assembling/manufacturing plant): to re-tin leads showing coating weakness during solderability test or to repair bent leads.
|