Photovoltaic

There are no translations available.

Solar panels

For cells, modules & panels:


Physical and chemical expertise
Full construction analysis, including X-Ray
Failure analysis

 

 

 

 

 

 

Problem Solving

Solar panel

 

 

 

Solar-panel

 

 

 

Solar panel

Benchmarking
Environmental & performance tests


Techniques:

FIB / CROSS POLISHER
SEM / EDX
TEM / EELS / EDS
SIM / TOFSIMS / MICRO FTIR
– …






See more about the Techniques used  for  Photovoltaic Analysis.

 

 

Power Inverters


Technological analysis:
From a simple construction analysis (benchmarking) to a critical analysis (process, design) using our database and our knowhow.

Component choice
Serma can help the customer to do the right trade-offs through construction analysis results, crossing database information (guideline), and drive qualification plans

Problem solving (failure analysis)
Based on our component experts experience

Robustness, Screening, Qualification, Reliability test plans
Our ETM BU can define all those type of tests (according the component choice, the mission profile, etc.)

Test achievement:
Our lab can run tests using its equipments, and coach or
subcontract mechanical tests (vibrations, shocks)

An expertise centre from the bare die to the system

Electrical tests & characterisation

Development of test solutions 

Go / No Go Test, Up-Screening (7000 programs)

Parametric characterisation (AC/DC, functional)

Customized evaluation (non-standard specifications
----ESD, Latch-up, Electromigration

 

Environmental tests

Thermal cycles shocks

Temperature & humidity

Pressure Cooker & Hast

High-temperature storage, Burn-in,

HALT, HASS




Power Cycling Test System

Possible electronics under test : Diode, MOSFET, IGBT, etc.

Main characteristics:

---1 to 20 DUT (Device Under Test)
---Maximum Power available: 12kW (20V, 1200A)Switching ---frequency (for MOSFET/IGBT) : up to 10kHz

---Cycles controlled in:
------time (set tON and tOFF)
------or temperature (set TMAX et TMIN)

---Air cooled Aluminum heat sink

Evolution 1 :

---DUT mounted in a climatic chamber (T and RH)

Evolution 2 :

---DUT switching high voltages and high currents (high capacitance capacitor discharge), to be as close as possible to the mission profiles

6 constraints can be combined (under conditions) :

---Temperature and deltaT

-------70°C / +200°C (>±10°C/min)

---Relative Humidity
------10% to 98% at Patm ; 10% à 95% at 91mbar

---Vacuum
------Patm down to 20mbar

---Voltage, current
------6kV, 2A
------10V, 1000A
------330V, 30A (x2)

Power supplies (examples) :

Know how


Serma Technologies know how is based on :
lot of analysis & test plans achieved in several Power Electronics fields of activity
Railway
Aeronautics
Space
Automotive
Oilfield

Lot of R&D projects through European & French clusters :
Menkar : To design a new inverter for three-phased electrical machine
Memoire
….
=> IGBT and diodes devel. / module protection / measurements / Reliability

Further informations !
CALL US : +33 (0)557 26 08 88
Business : Benjamin CROUILLERE, Sales Engineer
Technical : Laurent CALLET, Grenoble Lab Manager

To leave a message, click here